Return to Home Page
Type XW 11198/11199/11200
Hydraulic pump for water/glycol applications




The high pressure Type XW hydraulic pump is suitable for a wide range of fluids including water-based solutions and oil-based fluids. Separation of the lubricating oil and the pumped fluid is achieved by the installation of a cavity between the cylinder block and the case. Bypass from the pistons is collected in this cavity and returned to the inlet side of the pump.
The pump is available with either three or six pistons. The six piston version can be supplied
with duplex deliveries which may be used for simultaneous high and low pressure applications when used with an automatic unloading valve.
Additional variations are possible by varying the input speed to a maximum of 1,800rpm.

Pressure and flow combinations

Pump No. No. of pistons
size and stroke
Theoretical
flow (cc/rev)
Max pres. (bar)
Full stroke pumps
11198 - 40 - HL 3 x 0.437 4.80 690
11198 - 41 - HL 3 x 0.500 6.25 663
11198 - 42 - HL 3 x 0.562 7.90 524
11199 - 43 - SL 3 x 0.625 9.79 423
11199 - 44 - SL 3 x 0.687 11.79 351
11200 - 41 - SL 6 x 0.500 12.50 331
11200 - 42 - SL 6 x 0.562 15.80 262
11200 - 43 - SL 6 x 0.625 19.58 211
11200 - 44 - SL 6 x 0.687 23.58 175
1/3 stroke pumps
11198 - 50 - HL 3 x 0.437 x 1/3 1.59 870
11198 - 51 - HL 3 x 0.500 x 1/3 2.08 690
11198 - 52 - HL 3 x 0.562 x 1/3 2.63 524
11199 - 53 - SL 3 x 0.625 x 1/3 3.26 423
11199 - 54 - SL 3 x 0.687 x 1/3 3.93 351
2/3 stroke pumps
11198 - 60 - HL 3 x 0.437 x 2/3 3.20 870
11198 - 61 - HL 3 x 0.500 x 2/3 4.16 690
11198 - 62 - HL 3 x 0.562 x 2/3 5.26 524
11199 - 63 - SL 3 x 0.625 x 2/3 6.53 423
11199 - 64 - SL 3 x 0.687 x 2/3 7.86 351
Material
Stainless steel wetted parts; cast iron casing. Weight 40 Kg.

Installation

Rotation is bi-directional and the pump may be mounted horizontally or vertically. If vertical mounting is selected, our Technical Department should be consulted.
A suction filter of at least 125 microns should be used, and care should be taken to ensure that the filter is of adequate size and does not cause more than 300 mm Hg depression.
Pipes should be of sufficient size to give not more than 3.70 m/sec velocity in the delivery line and 1.20 m/sec in the suction line.
The suction line should be kept under positive pressure when the pump is stationary to allow priming.
We recommend that the fluid reservoir should be between 50 mm and 3 m above the suction port.



Return to Home Page